O AIPHONE
832841 TB-F-l-0986 ®
COMMUNICA
TELEPHONE TYPE INTERCOM TB-F series
MODELS TB-1F (single-way) TB-3F (three-way)
TB"6F (six-way) TB“12F (twelve-way)
COMMON TALK SELECTIVE RING
- INSTRUCTIONS
NAMES AND FUNCTIONS
Receiver cradle for wall mounting, included
(7) Handset
Station selector buttons
Microphone
Case
Coil cord
(7) Receiver
Terminal cord
(2) Paging button
Terminal box
Directory card
SPECIFICATIONS
* Power source:
Current consumption:
Calling:
Paging:
Wiring:
DC 12 volt. Use PS-12A (PS-12C in North America) AC adaptor. If your system does not in
clude door station or paging system, you may use PS-12S AC adaptor.
70 mA maximum per station.
Push-button station selection. An electronic tone sounds when the selected station button is
depressed.
Use PB-1 paging adaptor in conjunction with standard paging amplifier and speakers.
Up to 17 conductors may be required. Please refer to wiring diagram showing system that
meets your requirements.
BEFORE YOU INSTALL AND OPERATE THE EOUIPMENT
* Operation;
1. DO NOT HOLD HOOK SWITCH DOWN WHILE PICKING UP HANDSET. THE CALL
TONE SOUNDS THRU THE HANDSET RECEIVER ELEMENT AND COULD CAUSE
HEARING DAMAGE.
* Installation;
1. DO NOT CONNECT ANY TERMINAL ON ANY UNIT TO AC POWER LINES.
2. Be sure to remove plug of power supply from AC outlet before you open the unit or make
wiring connections.
3. Avoid running the connecting wires thru doors, windows or between furniture, which may
pinch and disconnectect the wires.
4. The intercom equipment must be installed in as dry and dust-free environment as possible.
* Maintenance;
1. Clean your intercom equipment with a soft cloth dampened with neutral household cleanser.
Never use thinner nor benzine, etc.
2. Do not splash water on the door station by hose, etc.
- 1 -
Prohibitions and precautions -
NEVER
NEVER
Page view 0
1 2 3 4 5 6 7 8

Summary of Contents

Page 1 - COMMUNICA

O AIPHONE832841 TB-F-l-0986 ®COMMUNICATELEPHONE TYPE INTERCOM TB-F seriesMODELS TB-1F (single-way) TB-3F (three-way) TB"6F (six-way) TB“12F (twel

Page 2 - INSTALLATION

FEATURES* Up to 13 stations can be connected in a system.* Common talk system for phone communication. (Conference calls can selectively include up

Page 3 - INSTALLATION OF TERMINAL BOX

WIRING REQUIREDTB-l F: 5 Conductors maximum TB-3F: 8 Conductors maximumTB-6F: 11 Conductors maximumTB-12F; 17 Conductors maximumRefer to the char

Page 4 - TB-12F ALL MASTE

TB-12F ALL MASTETB-12F PHONE SYSTEM with PAGING-4-

Page 5 - R PHONE SYSTEM

R PHONE SYSTEMI STATION 9STATION 10STATION 12I STATION 13/'—^/— ^ >1i<!^1^17©"T©2 ^2<<^2^2<^7©'7©3<^3^3^ 2,^3©7©4^4^

Page 6 - EQUIPMENT REQUIREMENTS

VARIATIONS TO STANDARD INSTALLATIONSAny combination of TB-F series phones and accessories shown on page 2 of this manual can be inter

Page 7 - ELECTRIC DOOR RELEASE

EXAMPLE NO. 3: TB-F SYSTEM WITH 2 DOOR STATIONS AND ELECTRIC DOOR RELEASE• Maximum of 2 door stations may be connected to up to 12 phones per system.N

Page 8 - OPERATION

OPERATIONCALLING;Pick up the handset and momentarily depress the selector button of desired station.RECEIVING;An incoming call is announced by an elec