Aiphone GH-1KD User Manual

Browse online or download User Manual for Security access control systems Aiphone GH-1KD. GH EU_H1_H4.ai

  • Download
  • Add to my manuals
  • Print
  • Page
    / 12
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Distributed by :
GH(E)0206A
http://www.aiphone.com/
ISO 9001
ISO 9001 Certified
JQA-0921
ISO 14001
ISO 14001 Certified
JQA-EM0453
Deming Prize
Deming Medal
Printed in Japan
(
E
)
VB48032AOZ
<
Direct-select call button
>
<
GH-1KD, GH-1KDS
><
GH-1MD
><
GH-HS
><
GH-1AD
>
<
GH-MK
><
Digital name scrolling
><
GH-BC, GH-VBC, GH-4Z
><
GH-BCX, GH-VBX
>
<
PS-2410DIN
><
PS-2410LD, PS-2410LC
>
4-call
Audio/Video + Name scroll
270
225
4416
135
320
4416
x 1
x 2
x 3
x 4
x 5
x 6
x 7
x 8
x 9
110
245
380
515
650
785
920
1055
1190
W
(mm)
GF-2B/3B
Back box total width
Joint pipe(x2)
W
44mm
25mm
200
mm
Do not recess back box
more than 15mm.
Two 2-module back boxes
UNIT DIMENSIONS
160
210
55.5
125 32
175
177
140
45 46
60
83.5
69
210
215
108.5
122.5
61
210
108.5
61
BlackRed
66
164
95
SPECIFICATIONS
BACK BOX DIMENSIONS
Power supply
Current consumption
Call tone
Talk & Video path
Communication
Door release
Wiring
Type of cables
: DC 24V supplied by PS-2410LC, PS-2410LD, PS-2410DIN (for GH-BC, GH-VBC, GH-NS/10K, GH-MK, GH-BCX)
: GH-BC: 0.9 A, GH-VBC: 0.9 A, GH-NS: 0.13 A, GH-MK: 0.18 A, GH-BCX: 0.35 A
: There are three different types of call tones from Entrance Station, Security Guard Station and Doorbell.
: Single channel, non-open
: Hands-free, voice-actuated communication (or press-to-talk communication)
: Connecting terminals: Between ELM - ELC (N/O) and ELB - ELC (N/C)
Specifications: less than 4A (resistance load), AC/DC 24V, dry closure contact
: Two single-pair cables
: Pair cable (solid wire not stranded), polyethylene insulated, diameter 0.65 to 1.0 mm
Module-mounting bracket
(supplied with GF-3F)
Tamper-proof screw & screwdriver
(supplied with GH-BC)
Cut out openings in advance.
GH-DA
GF-3F
GH-DP
GF-4P
GH-SW
GF-3B
Internal wiring connector
Joint pipe
Joint pipe
140
93
66.5
Total Residential Station
Number of Residential Stations within a Residence
Total Entrance Station
Total Security Guard Station
Wiring distance Entrance Station - Video Bus Control
Talk & Video path
Video Monitor
Type of Communication
Back light for GH-NS & GH-MK
Reception mode
Monitoring Entrance
Absence call memory
Additional call signaling device at Residential Station
Link programming
Save Link information to PC
Programmable room number displaying on GH-NS & GH-MK
Standard: 48 stations. Expanded: 500 stations
Up to 4 stations (up to 2 monitors)
Standard: 5 stations. Expanded: 16 stations
Standard: 2 stations. Expanded: 4 stations
300m
Standard: Single channel, non-open. Expanded: Single channel in the same common-sub line
GH-1KD, GH-1KDS: 3.5 inch Color LCD. GH-1MD: 4 inch B&W CRT
Hands-free, auto voice actuation (via Optional handset) or press-to-talk communication
Vacuum Fluorescence Display
Available
Available from Residential Station & *Security Guard Station *(requires modification)
Available, stored up to 20 calls
Available w/GH-RY relay
Program either one Entrance Station or Security Guard Station, and transfers link data to other
Available. Upload & download together with Resident information
From 1 to 6 digit. Numeral & Alphabet
250 stations
Up to 2 stations
5 stations
2 stations
100m
Single channel, non-open
4 inch B&W CRT
Full-duplex with handset
LCD with LED backlight
Not available
Not available
Not available
Not available
Program each Entrance Station/Security Guard Station one by one
Not available
3 or 4 digit. Numeral only
GH system
GF system
COMPARISON BETWEEN GH SYSTEM AND GF SYSTEM
295
mm
25mm 25mm
W
44mm
Three 3-module back boxes
Joint pipe(2 for each)
Do not recess back box more than 15mm.
All rights reserved. All statements valid at time of printing. The design and specifications are subject to change without notice for improvement.
Reliable Security
Variety of System Configurations
Easy Installation & Setup
MULTI-UNIT ENTRY SECURITY SYSTEM
GH SERIES
Hands-free Color Audio & Video
Entry Security System
32
125
175
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - GH SERIES

Distributed by :GH(E)0206Ahttp://www.aiphone.com/ISO 9001ISO 9001 CertifiedJQA-0921ISO 14001ISO 14001 CertifiedJQA-EM0453Deming PrizeDeming MedalPrint

Page 2 - Entry Security System

9SYSTEM CONFIGURATION10SYSTEM CONFIGURATIONTwo communication pathsSUB 1 SUB 2COMMON 1 COMMON 2One communication pathSUB 1 SUB 2COMMON 1 COMMON 2Commun

Page 3

9SYSTEM CONFIGURATION10SYSTEM CONFIGURATIONTwo communication pathsSUB 1 SUB 2COMMON 1 COMMON 2One communication pathSUB 1 SUB 2COMMON 1 COMMON 2Commun

Page 4 - RESIDENTIAL STATION

Distributed by :GH(E)0206Ahttp://www.aiphone.com/ISO 9001ISO 9001 CertifiedJQA-0921ISO 14001ISO 14001 CertifiedJQA-EM0453Deming PrizeDeming MedalPrint

Page 5

2GH SERIESIn today's society, an increasing demand is placed on features of a home. To meet a person's lifestyle, convenience and reliable s

Page 6 - SECURITY GUARD STATION

2GH SERIESIn today's society, an increasing demand is placed on features of a home. To meet a person's lifestyle, convenience and reliable s

Page 7

3RESIDENTIAL STATION4RESIDENTIAL STATIONSelect from five unit styles More Sensational Features Available!Talk mode can be switched to conventional Pre

Page 8 - SYSTEM COMPONENT

3RESIDENTIAL STATION4RESIDENTIAL STATIONSelect from five unit styles More Sensational Features Available!Talk mode can be switched to conventional Pre

Page 9

5ENTRANCE STATION6SECURITY GUARD STATIONSUB 1COMMON 1SUB 2COMMON 2Onecommunication pathTwo communication paths availableOnecommunication path< 1 &g

Page 10 - SYSTEM CONFIGURATION

5ENTRANCE STATION6SECURITY GUARD STATIONSUB 1COMMON 1SUB 2COMMON 2Onecommunication pathTwo communication paths availableOnecommunication path< 1 &g

Page 11

7SYSTEM COMPONENT8SYSTEM COMPONENTGH-VA / GF-VPGH-DA / GH-DPGH-SW / GF-4PGF-2 F/ GF-2BGF-3F / GF-3BGF-BPGH-AD / GF-APGH-NS / GF-NSPGH-10K / GF-10KP4.1

Page 12

7SYSTEM COMPONENT8SYSTEM COMPONENTGH-VA / GF-VPGH-DA / GH-DPGH-SW / GF-4PGF-2 F/ GF-2BGF-3F / GF-3BGF-BPGH-AD / GF-APGH-NS / GF-NSPGH-10K / GF-10KP4.1

Comments to this Manuals