AX Quikstart Guide
Pg. 1
AX QuikStart Guide
- INITIAL INSTALLATION INSTRUCTIONS -
Before proceeding with the installation of the AX system, please review these instructions.
1. The complete AX System Installation & Operation Manual is located on the CD included with the CEU.
2. The software program to set up the CEU is located on the CD as well. The CEU must be congured specically for
your system in order for it to function properly.
3. Included with the CEU is a USB to serial converter, along with a gender changer. This is supplied to allow any PC
with a USB port to be used to program the AX CEU.
#96501
1010
Door Station Ports
RJ-45 jacks
Door Release Contacts
Each contact can be programmed
to be either N/O or N/C. Contact
rating 500mA. Use the RY-24L for
higher current devices.
Master Station Ports
RJ-45 jacks
Open collector outputs for
video signal trigger (top)
AX-320 Add-on CEU ports (bottom)
RJ-45 jacks
Video Outputs.
Each talk path has its own output.
When connecting to a DVR, two
channels must be used.
Telephone Output
Connects to Viking Model K-1900-5 Dialer
Two 24V DC inputs
Parallel inputs on one PS-2420UL
for audio-only systems
RS232 port
Used for programming
On/Off power switch
Connecting Central Exchange Unit to Computer via USB-to-Serial Converter:
1. Connect power supplies and turn on CEU.
2. If a serial output is not available on your PC, install the USB
driver that comes with the converter on your PC.
3. Attach the gender changer to the converter and plug
converter into the RS232 port on the AX Exchange unit.
4. Plug the other side of the USB converter into the USB
port on the computer.
This will allow you to upload and download program information
between the PC and CEU via the AX Setup Tool program.
DB9 F/F
Gender Changer
USB-to-Serial
Converter
To USB Port
on PC
Actual components
(supplied with AX-CEU)
RS232C Port
AX-248C
16-7/8”
(
13-3/16” Depth
)
3-7/16”
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - AX QuikStart Guide

AX Quikstart GuidePg. 1AX QuikStart Guide- INITIAL INSTALLATION INSTRUCTIONS -Before proceeding with the installation of the AX system, please review

Page 2 - Installing the Software

AX Quikstart GuidePg. 10AX Series CAT5e wire Installation Do’s and Don’tsDo Run all cables in a “Star” conguration. That is to say that they all ema

Page 3

AX Quikstart GuidePg. 11• AX-CEU Power LED ashing: Possible incorrect program setting for the Central Exchange Unit. If there is no add-on exchang

Page 4

Aiphone Communcation Systems1700 130th AVE N.E.Bellevue, WA 98005(425) 455-0510FAX (425) 455-0071Toll Free Technical Support:1-800-692-0200E-mail tech

Page 5

AX Quikstart GuidePg. 2Installing the SoftwareInsert the CD or download the AX software from our website. Open the AXSetup.exe program and you will b

Page 6 - 3-7/16”

AX Quikstart GuidePg. 33) Door StationStep 1: Fill in location name of each door station if desired. (Not required. Names are not stored in the CEU)

Page 7

AX Quikstart GuidePg. 44) Time-OutStep 1: Set Call-in time for door stations from 10 to 600 seconds or to innite if the call is to ring until it is

Page 8

AX Quikstart GuidePg. 54) Saving / UploadingStep 1: Connect your PC / Laptop to the AX-CEU as shown on page 1. Use the supplied USB-to-Serial Conver

Page 9

AX Quikstart GuidePg. 6BLOCK DIAGRAM:AX-084C16-7/8” (13-3/16” Depth) 3-7/16” CAT-5e(max dist. 980’)PTAX-DV7-11/16"3-15/16" 1"AX-DV7-11

Page 10 - AX Quikstart Guide

AX Quikstart GuidePg. 7AX-084C16-7/8” (13-3/16” Depth) 3-7/16” Max. distance from each door station to AX-CEU = 980’ with CAT5e.Max. distance from ea

Page 11 - Basic Troubleshooting:

AX Quikstart GuidePg. 8AX-084C16-7/8” (13-3/16” Depth) 3-7/16” Brown V+ to Coax CoreRed V- to Coax BraidYellowGreenOrangeBlueMonitor / DVR5’ maxBlueW

Page 12

AX Quikstart GuidePg. 9You can use a standard 2-conductor cable when using an audio-only sub station. At the CEU, splice the 2-conductor cable onto a

Comments to this Manuals

No comments